BXK防爆控制箱,机旁防爆控制箱,防爆配电箱

BXK防爆控制箱,机旁防爆控制箱,防爆配电箱

参考价: 面议

具体成交价以合同协议为准
2016-06-02 04:50:54
643
产品属性
关闭
乐清威创防爆科技有限公司

乐清威创防爆科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

BXK防爆控制箱,机旁防爆控制箱,防爆配电箱主要用于1区或2区中含有爆炸性混合物为Ⅱ类B级T6组及以下爆炸危险场所,作为交流50Hz,额定电压至380V,线路中远距控制信号、电气等,并有信号指示灯。

详细介绍

BXK防爆控制箱,机旁防爆控制箱,防爆配电箱是由乐清威创防爆科技有限公司专业生产;

1 用途和适用范围
1 Purpose and scope
   BXK系列防爆控制箱(以下简称控制箱)是按GB3836.1~2设计和制造,配电箱主要用于1区或2区中含有爆炸性混合物为Ⅱ类B级T6组及以下爆炸危险场所,作为交流50Hz,额定电压至380V,线路中远距控制信号、电气等,并有信号指示灯。
BXK series explosion-proof control box (hereinafter referred to as the control box) is GB3836.1 ~ 2 design and manufacturing, distribution box is mainly used for zone 1 or 2 region containing explosive mixtures for class II B and below T6 group explosive dangerous location, as the exchange of 50Hz, rated voltage up to 380V, far distance control signal lines, electrical and other, and a signal indicating lamp.

2 产品型号和意义及基本参数
2 types of products and the significance and basic parameters
2.1 产品型号和意义
2.1 types of products and the significance
B XK - □ □ □ □
B XK - □ □
开关数(不装补0)
Number of switches (not 0)
信号灯数(不装补0)
Signal lamp number (not 0)
电流表数(不装补0)
The current table number (not 0)
按钮数(不装补0)
Button number (not 0)
控制箱
The control box
防爆
Explosion-proof
2.2 基本参数
2.2 basic parameters
   控制箱基本参数
Control box of basic parameters
1额定电压:380V
1 of the rated voltage: 380V
2.4 2额定电流:5A
2.42 of the rated current: 5A
2.5 控制箱的防爆标志为dⅡBT6;
Explosion-proof control box is the 2.5 sign D Ⅱ BT6;
2.6 控制箱进线配用电缆zui大外径为26mm;
2.6 control box with cable into the line of the largest diameter of 26mm;
3BXK防爆控制箱,机旁防爆控制箱防爆配电箱在下列情况下能够可靠工作
3 control box can work reliably in any of the following circumstances
3.1 周围空气温度上限值不超过+40℃,下限值不低于-20℃,且24小时内的平均值不超过+35℃;
3.1 the temperature of the air around the upper limit of not more than +40 ℃, lower value not lower than -20 ℃, and within 24 hours of the average value of not more than +35 DEG c;
3.2 安装地点的海拔不超过2000m;
3.2 installation site elevation not exceeding 2000m;
3.3 在无显著摇动、振动和冲击的地方;
3.3 significant shake, no vibration and shock;
3.4 安装地点zui湿月平均zui大相对湿度不超过95%,同时该月的月平均温度不低于+25℃;
3.4 installation location the wettest month average maximum relative humidity of not more than 95%, while the average monthly temperature of the month is not lower than +25 ℃;
3.5 污染等级为3级;
3.5 of the pollution level of 3;
3.6 安装类别为Ⅱ、Ⅲ类;
3.6 installation of class II, class iii;
3.7 防护等级:IP54。
3.7 protection grade: IP54.
4BXK防爆控制箱,机旁防爆控制箱防爆配电箱 主要结构及外形安装尺寸
The 4 main structure and dimensions
4.1 主要结构
The 4.1 main structure
   控制箱外壳采用钢板焊接而成,腔内装有按钮、信号灯等元件,通过操作机构及外壳手柄进行操作,且有指示灯显示。
The control box shell is welded by steel plate, cavity is provided with a button, signal lamps and other components, operated by the operating mechanism and the shell handle, and the indicating lamp display.
5 使用与维修
5 use and repair
5.1 将控制箱安装固定好,将进出线腔盖打开,把电缆通过引入装置接至接线端子上,接好内外接地线,检查无误后合上盖,用紧固件紧固,并把压紧螺母旋紧使电缆密封,完毕后即可使用。
5.1 control box installed and fixed, pass in and out line cavity cover is opened, the cable introducing device connected to the terminals, connected inside and outside the ground, check and correct after the upper cover, with the fastening piece, and the pressing nut is screwed up the cable sealing, can after use.
5.2 控制箱不得随意拆卸,维修进先断开电源后,才能开盖维修,维修时不得损坏隔爆面,维修后隔爆接合面涂204-1防锈油,并将盖合好,用螺栓紧固后才能使用。
5.2 control box shall not disassemble, repair in first disconnect the power, in order to open repair, repair shall not be damaged flameproof surface, after the repair of flameproof joint 204-1 coated anti-rust oil, and will cover good, used to bolt after.

专业生产:防爆配电箱,铸铝防爆箱,不锈钢防爆箱,防爆接线箱,防爆照明配电箱,防爆动力配电箱,防爆配电柜,防爆控制箱,BZC51防爆操作柱,防爆应急灯,防爆荧光灯,防爆无极灯厂家,防爆正压柜,防爆投光灯,柳市防爆箱,防爆断路器等,质量三包,凡购买本公司产品,质保三年,本公司证件齐全,价格实惠!

www.shbxmd.com www.zj8899.com www.jiang-ex.com www.fangbaoa.com  www.zj-88.com  www.wcfangbao.com  www.exbaidu.com  www.wzfangbao.com 

上一篇:威创防爆配电箱技术产品 下一篇:(IIC级)BXMD51钢板防爆(动力)配电箱*
提示

请选择您要拨打的电话: