预制分支电力电缆

预制分支电力电缆

参考价: 面议

具体成交价以合同协议为准
2022-02-01 08:59:56
146
产品属性
关闭
山西通用电缆科技有限公司

山西通用电缆科技有限公司

免费会员
收藏

组合推荐相似产品

产品简介

用途Application预制分支电力电缆可在住宅楼、办公室、宾馆、医院、商场等高层建筑使用,而且已扩展到公路、桥梁及隧道照明灯其它领域

详细介绍

用途 Application

预制分支电力电缆可在住宅楼、办公室、宾馆、医院、商场等高层建筑使用,而且已扩展到公路、桥梁及隧道照明灯其它领域。预制分支电力电缆作为一种新型建筑用线,是工厂按照用户要求的主、分支电缆型号、截面、长度及分支位置等指标,经过专业的一系列设备、生产流水线将其完成的带分支的电缆。

The prefad branch electrical power cable can be wildly applied to the tall buildings:dwelling house buildings,office buildings,guesthouses,hospital markets and so on,but also has expanded to the other realm:highway,bridge and tunnel illumination and so on.As a new type of building cable,prefad branch cables are produced according to the targets of consumer’s demands:type of the main and the branch cable,cross section,length and branch position,they are finished on the assembly line in the factory where the worker use a series of special purpose equipments .

产品特性 Product features

(1)绝缘电阻≥200MΩ   Insulation resistance ≥200MΩ.

(2)绝缘耐压≥3.5KV   Insulation withstand voltage ≥350KV.

(3)良好的气密性与防水性,即将分支接头浸入水中,在水与电芯之间测量绝缘电阻和工频耐压均符合(1)(2)要求。

Excellent air tightness and water proofing quality.When immerge branch joint water,measured insulation resistance between water and cable core,and power frequency withstand voltage meet the requirement of items (1)(2).

(4)分支接头的接触电阻小,接触电阻与等长的分支线的基准电阻之比≤1.2。

Little contact resistance of branch joint.The ratio vatio value of contact resistnce vs reference resistance of equal length branch line is equal to less than 1.2.

(5)ZA型阻燃预制分支电缆,护套的自烯时间≤1.2s,符合GB/T 18380.3-2008的要求。

For ZA type flame-retardant prefabricated branch cable,self extinguishing time of jacket is equal to or less than 12s and meets GB/T 18380.3-2008.

(6)NH耐火型电缆除了能正常的工作条件下供电外,还能在燃烧的情况下,保持90min的正常运行,符合GB/T 12666.3-2008的要求。

Besiddes power supply in normal workingcondition,fire-resistant type calbe can remain normal operation for 90min under burning condition and meets GB/T 12666.6-2008 .

(7)WDZA、WDNH清洁型预制分支电缆具有低烟、低毒、无卤、耐火、阻燃等优越性能。

WDZA、WDNH clean type prefabricated branch cable posses the features such as low-smoke、low-toxic and fire-resistance etc. 

(8)VV型电缆的长期允许温度为70℃,YJV型点缆的长期允许温度为90℃,YJV型预制分支电缆具有热稳定性和抗老化性。

Max.working temperature of copper core of VV type cable is 70℃ and that of YJV type cable is 90℃.YJV type prefabricated branch cable has excellent themal stability and aging resistance.
 
型号名称及使用范围 Type names and usable range

额定电压0.6/1KV铜芯、铜包铝芯预制分支电力电缆  Copper and TL prefab electrical cable with rated voltage 0.6/1KV

型号 Type

名称 Name

YDF-VV
YDF-VV(TL)

铜芯、铜包铝芯聚氯乙烯绝缘聚氯乙烯护套预制分支电力电缆
Polyvinly chloride insulated and sheathed prefab branch electrical power cable

YDF-ZAVV
YDF-ZAVV(TL)

铜芯、铜包铝芯聚氯乙烯绝缘聚氯乙烯护套阻燃预制分支电力电缆
Polyvinly chloride insulated and sheathed flame-retardant prefab branch electrical power cable

YDF-NHVV
YDF-NHVV(TL)

铜芯、铜包铝芯聚氯乙烯绝缘聚氯乙烯护套耐火预制分支电力电缆
Polyvinly chloride insulated and sheathed fire-resistant prefab branch electrical power cable

YDF-YJV
YDF-YJV(TL)

铜芯、铜包铝芯交联聚乙烯绝缘聚氯乙烯护套预制分支电力电缆
Cross linked polyethylene insulated polyvinly chloride sheathed prefab branch electrical power cable

YDF-ZAYJV
YDF-ZAYJV(TL)

铜芯、铜包铝芯交联聚乙烯绝缘聚氯乙烯护套阻燃预制分支电力电缆
Cross linked polyethylene insulated polyvinly chloride sheathed flame-retardant prefab branch power cable

YDF-NHYJV
YDF-NHYJV(TL)

铜芯、铜包铝芯交联聚乙烯绝缘聚氯乙烯护套耐火预制分支电力电缆
Cross linked polyethylene insulated polyvinly chloride sheathed fire-resistant prefab branch power cable

YDF-WDYJV
YDF-WDYJV(TL)

铜芯、铜包铝芯交联聚乙烯绝缘聚氯乙烯护套低烟无卤预制分支电力电缆
Cross linked polyethylene insulated polyvinly chloride sheathed low-smoke and no-halofen prefab branch l power cable

YDF-WDZAYJV
YDF-WDZAYJV(TL)

铜芯、铜包铝芯交联聚乙烯绝缘聚氯乙烯护套低烟无卤阻燃预制分支电力电缆
Cross linked polyethylene insulated polyvinly chloride sheathed low-smoke and no-halofen flame-retardant prefab branch power cable

YDF-WDNHYJV
YDF-WDNHYJV(TL)

铜芯、铜包铝芯交联聚乙烯绝缘聚氯乙烯护套低烟无卤耐火预制分支电力电缆
Cross linked polyethylene insulated polyvinly chloride sheathed low-smoke and no-halofen fire-resistant prefab branch power cable

产品结构 Product structure
生产范围 Manufacture range

主干电缆标称截面(mm2)
Main cable cross section

支线电缆标称截面
Branch cable cross section

10

6

 

 

 

 

 

 

 

 

 

16

10

16

 

 

 

 

 

 

 

 

25

10

16

25

 

 

 

 

 

 

 

35

10

16

25

35

 

 

 

 

 

 

50

10

16

25

35

50

 

 

 

 

 

70

10

16

25

35

50

70

 

 

 

 

95

10

16

25

35

50

70

95

 

 

 

120

10

16

25

35

50

70

95

120

 

 

150

10

16

25

35

50

70

95

120

150

 

185

10

16

25

35

50

70

95

120

150

185

240

10

16

25

35

50

70

95

120

150

185

300

10

16

25

35

50

70

95

120

150

185

400

10

16

25

35

50

70

95

120

150

185

500

10

16

25

35

50

70

95

120

150

185

630

10

16

25

35

50

70

95

120

150

185

800

10

16

25

35

50

70

95

120

150

185

备注:绞合的预制分支电力电缆主干电缆的截面为300mm2
Attention: the maximum cross section of the main cable of twisted prefab branch electrical power cable is 300mm2 