Introduction:The R-4OX is a 32mm industrial Oxygen sensor, ideal for fixed gas detectors.
Key Features: robust design, proven reliability and high performance
Erformance Characteristics
Output signal | 0.10 ± 0.03 mA |
Zero Current (Offset) | < 0.6% vol. O2 |
T90 Response Time | < 15 seconds |
Measurement Range | 0 - 25% Oxygen |
Maximum Overload | 30% Oxygen |
Linearity | Linear |
Recommended Load Resistor | 100 ohms |
Environmental Details
Temperature Range Continuous | -30℃to +50℃ |
Pressure Range | 800 to 1200 mbar |
Operating Humidity Range | 5% to 95% RH |
Important Note:
All performance data is based on conditions at 20℃, 50%RH and 1 atm, using CCR Scientific recommended circuitry.
Sensor performance is temperature dependent, and please contact CCR Scientific for temperature performance other than 20℃.
Lifetime Details
Long Term Output Drift | < 5% per annum |
Recommended Storage Temp | 0℃to 20℃ |
Expected Operating Life | > 24 months in air |
Standard Warranty | 24 months from date of dispatch |
Intrinsic Safety Data
Maximum current in normal operation (pure O2) | 0.01 A |
Maximum o/c Voltage (10 to 99% O2) | 0.9 V |
Maximum s/c Current (10 to 99% O2) | 0.5 A |
Toxic gases at TLV levels will have no cross-sensitivity effect on CCR-Scientific oxygen sensors. At very high levels (i.e. percent levels), highly oxidising gases (e.g. ozone, chlorine) will interfere to the extent of their oxygen equivalent, but most other commonly occurring gases will have no effect.
Acid Gases
IMPORTANT NOTE: Acid gases such as CO2 and SO2 will be absorbed by the electrolyte and tend to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signal of approximately 0.3% of signal per 1% CO2. CCR Scientific oxygen sensors are not suitable for continuous operation in concentrations of CO2 above 25%.