| S-240-5 | S-240-7.5 | S-240-12 | S-240-15 | S-240-24 | S-240-30 | S-240-48 |
直流输出电压 | 5V | 7.5V | 12V | 15V | 24V | 30V | 48V |
输出电压容差(注2) | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% |
额定输出电流 | 40A | 30A | 20A | 16A | 10A | 8A | 5A |
输出电流范围 | 0-40A | 0-30A | 0-20A | 0-16A | 0-10A | 0-8A | 0-5A |
纹波及噪音(注3) | 150mVp-p | 200mVp-p | 150mVp-p | 150mVp-p | 180mVp-p | 180mVp-p | 240mVp-p |
进线稳定度(注4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±1% |
负载稳定度(注5) | ±1% | ±1% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±1% |
直流输出功率 | 200W | 225W | 240W | 240W | 240W | 240W | 240W |
效率 | 78% | 80% | 82% | 83% | 84% | 85% | 87% |
直流电压可调范围 | 4.5―5.8V | 6―9V | 10―13.2V | 20―28V | 13.5―18V | 27―33V | 41―56V |
输入电压范围 | 88―132VAC/176―264VAC 由开关选择 47―63Hz; 248―370VDC |
输入电流 | 5A/115V 2.5A/230V |
冲击电流 | 冷启动电流 18A/115V 36A/230V |
漏电流 | <3.5mA/240VAC |
过载保护 | 105%―135% 类型:切断输出 复位:自动恢复 |
过电压保护 | 105%―135% 类型:切断输出 复位:自动恢复 |
高温保护 | PR1>=40℃ FAN ON.<35℃ FAN OFF.>=70℃切断输出 |
温度系数 | ±0.03%/℃ (0―50℃) |
启动、上升、保持时间 | 100ms,50ms,30ms |
抗震性 | 10―500Hz,2G 10min,/1周期,时长60分,各轴 |
耐压性 | 输入输出间:3KvAC输入与外壳:1.5KvAC输出与外壳:0.5KvAC |
隔离电阻 | 输入输出间,输入与外壳,输出与外壳:500VDC/100MΩ |
工作温度、湿度 | -10℃―+50℃(参考输出特性图),20%―90%RH |
存储温度、湿度 | -20℃―+85℃,10%―95%RH |
外形尺寸 | 215*115*50mm |
重量 | 0.9Kgs |
安全标准 | UL1915,EN60950 |
EMC标准 | EN55022,IEC1000-42.3.4.5 IEC10003-2.3 |
|
注::1、以上参数测试条件为:230VAC输入,额定负载,25℃ 70%Rh。 2、容差:包括设定容差,线路稳定度,负载稳定度(注5)。 3、纹波测试:20MHz用“A12”双绞线,中断用0.1uF&47uF电容器短路。 4、进线电压稳定度测试:满负载时进线电压到电压。 5、负载稳定度测试:负载从0%到99%。
|