GF2 Series of diesel generating set

GF2 Series of diesel generating set

参考价: 面议

具体成交价以合同协议为准
2022-08-26 08:37:42
900
产品属性
关闭
福安市春飞电机有限公司

福安市春飞电机有限公司

免费会员
收藏

组合推荐相似产品

产品简介

GF2系列柴油发电机组

详细介绍

THE FORMATION INSTRUCTIONS OF DIESEL GEN-SETS
1.Diesel generating sets
all diesel generating sets include diesel engine, alternator and control box and all the alternators have been made by Chun Fei Motor Co.,Ltd.
2. Stating method of gen-sets.
a).manual switcher
b).automatic starting wholly: when electric supply has been stopped, the gen-sets can start three times automatically in 3-28 seconds (time can be adjustable) between electric supply and gen-sets need 6-8 seconds. it will spend 12 seconds to accept load when electric supply resumed, gen-set will maintain 23-230 seconds, then closes down automatically.
3.Control system
apparatus: voltmeter, frequency meter, amperage meter, voltmeter of battery, meter of water temp., oil meter. control section: starting handler, key type switch, inductive type self-protection switch, and indicator.



OTHER MAIN PERFORMANCE:
1.Voltage steady-state regulation±1% fluctuation ratio 1.5%
transient-state regulation -15~20% steady time 5s
Frequency steady-state regulation 5% fluctuation ratio 1.5%
Transient-regulation ±1% steady time 5s
2.The noise of gen-sets should be no more than 85db(a).
The fuel consumption is no more than 2.5kg/kw.h.

ADDITIONAL EQUIPMENTS
1.Automatic starting control panel
this panel includes manual control panel, time relay, indicator testing button, alarm resetting button, over speed inductive switch, alarm buzzer of low-voltage of battery, starting malfunction alarm.
2.Automatic changing-over panel
When the electric supply has been stopped, the gen-sets will start automatically.
when the electric supply has remended, the gen-sets will halt automatically.
3.Automatic diesel generating sets with inligence performance and prinepipe.
4.Booster, battery charger, alarm buzzer, attached inductive protectiont switcher.
5.Trailer-behind movable power station.
6.Soundproof diesel generating sets.

Gensets
Model
Rated
Output
(kw)
Rated
Current
(a)
Fuel
Consumption
(g/kw.h)
Starting
Method
Engine
Model
Dimensions
(mm)
N.w.
(kg)
GF2-10KW 10 18.1 <257 12V D.C
Electric
295AD 1380X640X1000 600
GF2-12KW 12 21.6 295AD 1380X640X1000 600
GF2-15KW  15 27 395AD 1640X650X980 650
GF2-20KW 20 36 495AD 1780X750X1000 750
GF2-24KW 24 43.3 495AD 1780X750X1000 780
GF2-30KW 30 54.1 495AZD 1820X750X1000 920
GF2-40KW 40 72.1 <238 24V D.C
Electric
4135D 2200X710X1900 1610
GF2-50KW 50 90.2 4135D 2280X820X1350 1750
GF2-64KW 64 115.4 *4135D 2400X850X1400 1800
GF2-75KW 75 135.3 *6135 2400X850X1400 2330
GF2-90KW 90 162.3 *6135D 3000X900X1370 2500
GF2-100KW 100 180.3 *6135AD 3000X900X1370 2650
GF2-120KW 120 216.5 238 *6135AZD 3000X900X1370 2800
GF2-150KW 150 270.6 250 *12V135D 3300X960X1650 3500
GF2-200KW 200 360.8 250 812V135AD 3210X1320X1920 3750
GF2-250KW 250 451 250 *12V135D 3210X1320X1920 3850
GF2-300KW 300 541.2 250 W12V135AZD-1 3300X1770X1905 4300
GF2-320KW 320 577.3 228 W12V135AZL 3300X1770X1905 4350
. Voltage: 400/230V
. Rotation Speed: 1500/1800 r.p.m/min
. Cooling Method: Closed Circulation Cooling
. Freq.: 50Hz/60Hz
. Power Factor: 0.8(LAG)
. Triple Harmonic STC series or brushless exciting or TFW series of Alternator
提示

请选择您要拨打的电话: