4CFC-City一氧化碳传感器

4CFC-City一氧化碳传感器

参考价: 面议

具体成交价以合同协议为准
2024-03-18 11:57:42
113
产品属性
关闭
河南英科传感技术有限公司

河南英科传感技术有限公司

免费会员
收藏

组合推荐相似产品

产品简介

河南英科传感技术有限公司是**的以气体传感器销售与技术服务的科技型公司。英科传感技术公司提供的传感器类型有红外气体传感器、激光甲烷气体传感器、电化学气体传感器、半导体气体传感器、催化燃烧式气体传感器、热导型气体传感器、热线型气体传感器、微量粉尘气体传感器、PID光离子型气体传感器、烟雾传感器、TVOC气体传感器、大颗粒粉尘气体传感器、传感器及其传感器模块可用于检测多达200余种气体。

详细介绍


Technical Specifications


MEASUREMENT:

Operating Principle

3-electrode electrochemical

Measurement Range

0-1000 ppm CO

Maximum Overload

2000 ppm CO

Filter

To remove acid gases and

hydrocarbons

Sensitivity*

0.07 ± 0.015 µA/ppm

Response Time (T 90 )*

< 20 Seconds

Baseline Offset (clean air)*

< ±2 ppm equivalent

Zero Shift (-40°C to +50°C)*

< + 12 ppm equivalent

Repeatability *

< ±3%

Linearity*

Within ±5%


ELECTRICAL:

Recommended Load Resistor

5Ω

Bias Voltag

Not required


MECHANICAL:

Housing Material

Noryl 110

Weight

5 g (nominal)

Orientation

Any


ENVIRONMENTAL:

Typical Applications

Portable life safety

Operating Temperature Range:

Continuous

Intermittent

 

-20°C to +40°C

-40°C to +55°C

Operating Pressure Range

Operating Humidity Range:

1 atm ± 10%

 

Continuous

15% to 90% RH non-condensing


INTRINSIC SAFETY DATA:

Maximum at 2000 ppm

0.2 mA

Maximum o/c Voltage

1.3 V

Maximum s/c Current

<1.0 A


LIFETIME:

Long Term Output Drift*

< 5% per annum

Recommended Storage Temp

10°C to +30°C

Expected Operating Life

2 years in air

Storage Life

6 months in original packaging

Standard Warranty

18 months from date of despatch


IMPORTANT NOTE: 

      All performance data is based on conditions at 20°C, 50%RH and 1 atm, using City Technology recommended circuitry.

Sensor performance is temperature dependant. For sensor performance at temperatures other than 20°C, please contact City Technology.

        Specifications are valid at 20°C, 50% RH and 1013 mBar, using City Technology recommended circuitry.

       Performance characteristics outline the performance of sensors supplied within the first 3 months.

        Output signal can drift below the lower limit over time.


Poisoning

     CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments, and operation.

      When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.


Cross Sensitivity Table

       Whilst CiTiceLs are designed to be highly specific to the gas they are intended to measure, they will still respond to some degree to various other gases. The table below is not exclusive and other gases not included in the table may still cause a sensor to react.

      IMPORTANT NOTE : The cross sensitivity data shown below does not form part of the product specification and is supplied for guidance only. Values quoted are based on tests conducted on a small number of sensors and any batch may show significant variation. For the most accurate measurements, an instrument should be calibrated using the gas under investigation.


Gas

Concentration Used (ppm)

Reading (ppm CO)

Carbon Monoxide

50

50

Hydrogen Sulfide

20

<5

Sulphur Dioxide

20

<5

Nitrogen Dioxide

20

-5 ≤ X$ ≤ 0

Nitric Oxide

50

<25

Chlorine

0.5

0

Hydrogen

200

~25

Ethylene

100

100

Carbon Dioxide

5000

0

Ammonia

50

0

Methanol

200

0

热线电话 在线询价
提示

请选择您要拨打的电话: